Specifications
Model name |
Indoor unit |
FTKT35TV16WC |
FTKT50TV16VC |
FTKT60TV16UC |
Outdoor unit |
RKL35TV16WC |
RKT50TV16VC |
RKT60TV16UC |
Power supply |
1 50Hz 230V |
1 50Hz 230V |
1 50Hz 230V |
(220-240V) |
(220-240V) |
(220-240V) |
|
Power supply intake |
Outdoor unit |
Outdoor unit |
Outdoor unit |
Cooling capacity Rated Full/Half (min.~max.) |
kW |
3.52 / 1.76 (1.07 ~3.7) |
5.28/2.64 (1.75~5.7) |
6.2/3.1 (1.75~6.5) |
Cooling capacity Rated Full//Half (Min.~Max.) |
Btu/h |
12000 / 6000 (3650~12600) |
18000/9000 (6000~19500) |
21200/10600 (6000~22200) |
Power consumption Rated Full/Half (min.~max.) |
W |
1200 / 385 (210 – 1200) |
1790/582(370-1950) |
1970/722 (350-2100) |
Annual Power consumption |
kWh |
682.27 |
1024.93 |
1202.77 |
ISEER / Star Rating |
Wh/Wh |
3.99 / 3* |
3.99 / 3* |
3.99 / 3* |
Voltage Range |
V |
160-265 |
160-265 |
160-265 |
Operating current |
Cooling |
A |
5.43 |
7.86 |
8.67 |
Indoor unit |
Panel colour |
|
White |
White |
White |
Dimensions HxWxD |
mm |
298 x 800 x 229 |
298 x 885 x 229 |
298 x 885 x 229 |
(Package dimensions) |
|
375 x 895x 325 |
375 x 980 x 325 |
375 x 980 x 325 |
Weight (Gross) |
kg |
10(14) |
11(16) |
11(16) |
Airflow rate *1 X(Y) |
m3/min. |
13.4(11.9) |
16.2 (14.3) |
16.6 (15.4) |
Feet3/min (CFM) |
473(420) |
572(505) |
586(544) |
Operation sound H/M/L/SL |
Cooling |
dBA |
40/36/32/29/26 |
45/42/40/38/35 |
47/45/43/40/38 |
Outdoor unit |
Dimensions (HxWxD) |
mm |
550x675x284 |
595x845x300 |
595x845x300 |
(Package dimensions) |
|
620x825x400 |
680x1035x410 |
680x1035x410 |
Weight (Gross) |
kg |
22 (28) |
29 (36) |
33 (40) |
Operation sound (H) |
Cooling |
dBA |
51 |
54 |
56 |
Refrigerant (Amount) |
|
R32 (0.53 kg) |
R32 (.68kg) |
R32 (1.00 kg) |
Breaker size |
A |
15 |
20 |
20 |
Piping length |
Charge-less |
m |
10 |
10 |
10 |
Max. length |
m |
20 |
20 |
30 |
Max. height |
m |
15 |
10 |
20 |
Piping connection |
Gas/Liquid |
mm |
9.5/ 6.4 |
12.7/ 6.4 |
12.7/ 6.4 |
Operation limit |
Cooling |
oCDB |
19.4~54 |
19.4~54 |
19.4~54 |
Measurement conditions:
- Cooling capacity is based on: indoor temp. 27° CDB, 19° CWB; outdoor temp. 35° CDB, piping length 5 m.
- Sound levels are based on temperature conditions 1. above with 5m piping length. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.
Cooling and heating capacities above are rounded off to first decimal. 1TR (Ton of Refrigeration) = ~3.517 kilowatt.
* X(Y) X-Air flow rate during fan operation.
Y-Air flow rate in wet (cooling) condition.
Reviews